Professional Trachea Intubation Training Model - 12 Kg Gross Weight (EM-010A)

Product Details
Customization: Available
Net Weight: 10.0 Kg
Gross Weight: 12.0 Kg
Still deciding? Get samples of $ !
Request Sample
Diamond Member Since 2007

Suppliers with verified business licenses

Audited Supplier Audited Supplier

Audited by an independent third-party inspection agency

Importers and Exporters
The supplier has import and export rights
High Repeat Buyers Choice
More than 50% of buyers repeatedly choose the supplier
Years of Export Experience
The export experience of the supplier is more than 10 years
Self-branded
The supplier has 3 Self-brands, check the Audit Report for more information
to see all verified strength labels (22)
  • Professional Trachea Intubation Training Model - 12 Kg Gross Weight (EM-010A)
  • Professional Trachea Intubation Training Model - 12 Kg Gross Weight (EM-010A)
  • Professional Trachea Intubation Training Model - 12 Kg Gross Weight (EM-010A)
  • Professional Trachea Intubation Training Model - 12 Kg Gross Weight (EM-010A)
  • Professional Trachea Intubation Training Model - 12 Kg Gross Weight (EM-010A)
Find Similar Products

Basic Info.

Model NO.
EM-010A
Package Size
62X53X33 Cm
Usage
Oral or Nasal Cavity Intubation
Transport Package
1 PCS/Carton
Specification
For adult
Trademark
EMSS
Origin
China
HS Code
9023000000
Production Capacity
1000 Unit/Units Per Month

Product Description

Introducing the Advanced Trachea Intubation Training Model, an essential tool designed specifically for healthcare education. Elevate your training sessions with this state-of-the-art model that mimics real-life scenarios, preparing medical practitioners for hands-on intubation procedures.
Model No.: EM-010A - Your Gateway to Advanced Medical Training Excellence

Professional Trachea Intubation Training Model - 12 Kg Gross Weight (EM-010A)
Professional Trachea Intubation Training Model - 12 Kg Gross Weight (EM-010A)



Function Features That Empower Learning

Master the Art of Oral Cavity Intubation with Unparalleled Precision

Experience Seamless Nasal Intubation with Our Expertly Designed Model

 

Important Notice: Please ensure you have your own laryngoscope, tooth support, and resuscitator ready, as the simulator package does not include these items. Equip yourself with the essentials for an effective training experience.

Easily activate the alarm switch located at the base's back to commence your intubation practice.

 

Comprehensive Guide to Oral Cavity Intubation

Step 1: Thorough Preparation

A. Ensure the laryngoscope is in optimal condition; the headlight shines brightly when correctly connected to the handle.

B. Verify the integrity of the ductus cuff by injecting air with a syringe to check for leaks, then deflate the cuff as necessary.

C. Gently apply lubricant to the ductus front and cuff surface using a soft cloth for smooth operation.

D. Carefully lubricate the intratrachea with a brush dipped in lubricant to facilitate seamless insertion.

Step 2: Position the model on its back, tilt the head backward, and elevate the neck to align the mouth, pharynx, and trachea on a single axis.

Step 3: Stand by the model's head; use your left hand to hold the laryngoscope. Ensure a right angle alignment with the larynx. Insert the laryngoscope at the tongue root, gently lift to visualize the epiglottis edge, and proceed to view the glottis.

Step 4: Once the glottis is visible, gently insert the ductus with your right hand into the glottis, using a 'clockwise and counter-clockwise' twist. Insert approximately 4 cm for adults and 2 cm for children.

Step 5: Secure the ductus with a tooth support and then carefully remove the laryngoscope.

Step 6: Attach the resuscitator to the ductus and gently press to inflate, ensuring proper function.

Step 7: Proper ductus insertion into the trachea results in lung inflation. An erroneous esophagus insertion will cause stomach inflation accompanied by a warning beep.

Step 8: Secure both the ductus and tooth support post insertion into the trachea.

Step 9: Inflate the ductus cuff with a syringe to ensure a tight seal between the trachea wall and ductus, preventing air leaks, and backflow of vomit and secretions.

Step 10: Before removing the ductus, ensure the cuff is deflated using a syringe.

Step 11: Incorrect use of the laryngoscope, such as pressing against teeth, will trigger a warning beep for corrective action.

 

Nasal Intubation for Enhanced Learning:

Skillfully insert the ductus vertically into the nostril, guiding it through the nasal passage to the pharynx. Use your left hand to maneuver the laryngoscope, exposing the glottis; continue pushing the ductus with your right hand into the glottis. Follow the same process as oral intubation for subsequent steps.

 

Maintenance Guidelines for Prolonged Usability

1. Post-training, meticulously clean the ductus and cuff with a soft cloth to remove lubricant residues.

2. Clean the model using mild soap and water, avoiding immersion of the torso in any cleaning fluids or water.

3. Utilize only clean surfaces for operation. Steer clear of felt-tipped markers, ink pens, acetone, iodine, or any staining substances, and refrain from placing the torso on newspapers or inked lines.

4. If the warning beep fails to activate, please inspect the batteries for functionality. Should they be depleted, replace them promptly and reattempt the operation to ensure seamless performance.

5. To maintain the model's pristine condition and prolong its lifespan, please ensure the torso is meticulously cleaned following each training session. Moreover, conduct a general inspection routinely to guarantee its optimal condition.

6. Ensure the model is stored properly in a controlled environment between teaching sessions to preserve its integrity and readiness for subsequent use.

Packing:

Packing: 1 Set/Carton
Packing size: 62x53x33cm
N.W.: 10.0 KG
G.W.: 12.0 KG

 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now